Case History


Patient with prosthesis placement several years ago and current decrease in conductive hearing


Case Detail

Anatomy: Brain-Spine
Borders
Heather Borders, MD
Diagnostic Category: Developmental or Congenital
Created: over 6 years ago
Updated: over 6 years ago
Tags: PEDS
Modality/Study Types: CT
Activities:
Adobe32 PDF Imagej32 ImageJA

Case Images


Academic Case Revealer (Click to Expand)

Reveal Findings

Patient has a TORP; a goldenberg prosthesis with a hydroxyapitate cap attached to the stapes footplate and a head at the tympanic membrane with a notch over the malleus manubrium.

Reveal Discussion

Reconstruction of the ossicular chain is typically performed with synthetic prostheses. The PORP is the most commonly used prosthesis. It attaches to the medial surface of the tympanic membrane or occasionally to the long process of the incus and extends to the capitulum of the stapes. The stapes is left intact during placement of the PORP. If the diseased stapes is resected, a TORP is used to connect the medial surface of the tympanic membrane to an intact stapes footplate or oval window.

In this case, the stapes was resected and the prosthesis was attached to the stapes footplate, making it a TORP.

Most PORPs and TORPs are composites, consisting of a head and a shaft. The head is made of hydroxyapatite, a biocompatible calcium phosphate polymer that has the capacity to form bonds with bone and conduct vibratory energy. The biocompatibility of the head permits it to be in direct contact with the tympanic membrane without requiring a cartilage or tissue graft to prevent extrusion.

If the long process of the malleus is present, a prosthesis with a notched head is used. This was the case in this patient.

The shaft of the prosthesis is made of high-density polyethylene sponge. These materials are easy to cut and permit the shaft to be trimmed based on intraoperative measurement.

Reveal Diagnosis

Goldenberg prosthesis with subluxation and non communication with the oval window